<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="3.0" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher">ISPRS-Archives</journal-id>
<journal-title-group>
<journal-title>The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences</journal-title>
<abbrev-journal-title abbrev-type="publisher">ISPRS-Archives</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">Int. Arch. Photogramm. Remote Sens. Spatial Inf. Sci.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2194-9034</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.5194/isprs-archives-XLII-2-W11-269-2019</article-id>
<title-group>
<article-title>ENVIRONMENTAL MICROCLIMATE MANAGEMENT AND RISK IN THE UNESCO WORLD HERITAGE SITE OF VILLA BARBARO MASER (ITALY)</article-title>
</title-group>
<contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Bonora</surname>
<given-names>A.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Fabbri</surname>
<given-names>K.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Pretelli</surname>
<given-names>M.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
</contrib-group><aff id="aff1">
<label>1</label>
<addr-line>University of Bologna, Department of Architecture, Bologna, Italy</addr-line>
</aff>
<pub-date pub-type="epub">
<day>04</day>
<month>05</month>
<year>2019</year>
</pub-date>
<volume>XLII-2/W11</volume>
<fpage>269</fpage>
<lpage>276</lpage>
<permissions>
<copyright-statement>Copyright: &#x000a9; 2019 A. Bonora et al.</copyright-statement>
<copyright-year>2019</copyright-year>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri"  xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p>
</license>
</permissions>
<self-uri xlink:href="https://isprs-archives.copernicus.org/articles/XLII-2-W11/269/2019/isprs-archives-XLII-2-W11-269-2019.html">This article is available from https://isprs-archives.copernicus.org/articles/XLII-2-W11/269/2019/isprs-archives-XLII-2-W11-269-2019.html</self-uri>
<self-uri xlink:href="https://isprs-archives.copernicus.org/articles/XLII-2-W11/269/2019/isprs-archives-XLII-2-W11-269-2019.pdf">The full text article is available as a PDF file from https://isprs-archives.copernicus.org/articles/XLII-2-W11/269/2019/isprs-archives-XLII-2-W11-269-2019.pdf</self-uri>
<abstract>
<p>Indoor environment in heritage buildings can be cause of damage for architecture and artefacts which depend on several physical and chemical parameters: air temperature, relative humidity, volatile organic compounds, etc. How is it possible to evaluate their damage, or the risk of damages? How “aggressive” is indoor microclimate? The scientific literature proposes several different criteria for the evaluation of the risk of damages, especially in the field of museums, while there are few studies which take into consideration historic buildings. In this paper we propose an index – the Heritage indoor Microclimate Risk (HMR) – that allows to define the risk concerning the whole environment and not only the artefacts. Moreover, we propose its application to a real case study of a UNESCO Heritage World Site, obtained through indoor microclimate on-site monitoring and building simulation. The case study reported is Villa Barbaro, built in Maser (1554–1560) by the architect Andrea Palladio and registered in the UNESCO World Heritage Site list since 1996, as Palladian Villa of Veneto. The research is structured as follows: monitoring campaign of the microclimatic parameters; virtual modelling of Villa Barbaro and its validation (by comparing the simulated data and the monitored ones); construction of scenarios which can aid to guarantee the historic building’s conservation and the occupants’ comfort; definition of HMR. The innovative aspect of the proposed methodology is the use of a virtual building model of heritage buildings, to determine, through a single index, the degree of risk and the level of indoor microclimate aggression.</p>
</abstract>
<counts><page-count count="8"/></counts>
</article-meta>
</front>
<body/>
<back>
</back>
</article>